I would not install this fireplace today. I (DF) lived with this stove as a sole heat source in a different home in the early 1970's and can tell you it is not a design I recommend. Installation was incomplete - no adequate fire shielding was yet provided for this heater. The wall finish surface, such as drywall is not considered in evaluating the heat resistance or fire safety of the heating appliance.Īt left is a free-standing wood-burning fireplace installed by the author in the 1970's. Certifying agencies and standards for other countries are given below.įire safety clearance distances are measured from the closest point of the outer surface of the heating appliance to the closest point of nearby wall, floor or ceiling or to other combustible materials that might be nearby.
![horizon eclipse pellet stove control panel sticker horizon eclipse pellet stove control panel sticker](https://cdn11.bigcommerce.com/s-1r4c3e5sx1/images/stencil/1280x1280/products/4852/7923/50-1481-2__18639.1493914117.jpg)
Wood Heat Safety Organization also provide consistent recommendations for wood stoves that are not carry a certification label. The Canadian Standards Association (CSA) and the U.S. EPA who provide a List of EPA Certified Wood Heaters given below. Specific Fire Safety Clearance Distances for Un-Certified Wood Stoves & Pellet Stoves Watch out: Use whatever means necessary to create a 36-inch safety zone around any heating equipment that can get hot enough to burn a child. Child safety: 36" safety zone around Wood Stoves & Pellet Stoves Making a mistake can lead to a dangerous building fire.
#Horizon eclipse pellet stove control panel sticker code#
Some basic rule of thumb fire clearances for woodstoves are shown in the sketch at left.Ĭheck with your local fire marshall about local building code requirements for fire-clearance distances before installing and using a wood stove, coal stove, or other auxiliary heat source.
![horizon eclipse pellet stove control panel sticker horizon eclipse pellet stove control panel sticker](https://i.ytimg.com/vi/hzFxYOvgeAQ/hqdefault.jpg)
Notice also that the connection between the fireplace top and the flue is upside-down and that considerable leakage has occurred out of the flue onto the fireplace top. Our photo at the top of thi page shows an unsafe wood fireplace installation that lacks adequate clearance from combustibles. Fire Clearances for Flues for Woodstoves & Coal stoves We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. Comments on NFPA 211 "Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances".
![horizon eclipse pellet stove control panel sticker horizon eclipse pellet stove control panel sticker](https://cdn11.bigcommerce.com/s-1r4c3e5sx1/images/stencil/1280x1280/products/4845/7908/50-1475-4__07703.1493914089.jpg)
Wood stove or pellet stove heat shield construction & installation specifications.Įxamples of unsafe wood stove installations. Wood stove & pellet stove installation codes & standards, listings, labels, certifications. We discuss fire clearance distance specifications for wood stoves or coal stoves. The article includes standards for wood or pellet stove installations for various countries and it concludes with photos and descriptions of unsafe wood stove installations. We discuss child safety zones around wood and pellet stoves, the fire clearances for listed and un-listed wood or pellet stoves, and the construction and installation of a heat shield to reduce the required fire clearance distances around wood heating appliances. This article describes fire safety distances required between wood stoves and coal stoves and the nearest combustible surface. Woodstove fire clearance distance specifications: We have no relationship with advertisers, products, or services discussed at this website. InspectAPedia tolerates no conflicts of interest.